300µJ 1.54µm erbium glass microchip DPSS laser for multi-kilometer rangefinders

$0.00 USD
結賬時計算運費
Product Model:ER300

The ER300 is a 1535nm eye-safe erbium glass microchip DPSS laser that delivers ≥300µJ, 5ns pulses at 1–10Hz in a 25×8×6.8mm, 8.5g package. With −40°C to +65°C operating range, 1500G shock and 20–2000Hz / 20G vibration tolerance, it is a compact 1.54µm source for long-range LiDAR, laser rangefinders and target designation modules.

數量

Contact Us

Senior Engineer, Yilin

Tel : +86 28 81076698

WhatsApp : +86 18000520222

ERDI Pre-Sales Notice & Customer Information

(Please Read Before Purchase or Inquiry) Thank you for your interest in ERDI TECH LTD. We are committed to providing customers worldwide with high-precision, high-reliability laser products and technical solutions. Before placing an order, please read the following information carefully to better understand our company, services, and purchasing policies.

  • About ERDI​

     ERDI is a professional manufacturer specializing in the research, development, and production of laser modules, laser measurement systems, and related optoelectronic components.
    We integrate design, R&D, production, and sales, with a focus on safety, innovation, and precision.

    Our products are widely used in:

    • Industrial measurement and alignment systems
    • Scientific research and educational applications
    • Optical instrumentation and laser testing
    • Consumer and OEM laser solutions

    ERDI operates certified facilities and maintains rigorous quality control to ensure that every product meets international standards.

  • Global Presence and Trade Reliability​

    ERDI has established official stores on leading global platforms including Amazon, Alibaba International Station, and Made-in-China.com, allowing customers worldwide to purchase safely and conveniently. We are a verified and trusted factory, not a reseller, and we ensure that all transactions, quotations, and logistics follow transparent and secure trade practices.
  • Sample and Lead Time​

    To help customers evaluate our products and performance, we offer sample orders for most product categories.

    • Standard samplesare typically delivered within one week after order confirmation.
    • Customized modulesmay require additional processing time depending on design complexity and optical requirements.
      Our logistics team will provide real-time tracking and documentation for every shipment.
  • OEM / ODM / OBM Services​

     ERDI supports full-range customization including:

    • OEM (Original Equipment Manufacturing)– Products manufactured under your brand or part number.
    • ODM (Original Design Manufacturing)– Custom optical or mechanical design based on your specifications.
    • OBM (Original Brand Manufacturing)– Private-label solutions with our in-house R&D and branding support.

    We provide technical co-development, logo engraving, packaging customization, and batch production services to meet both small-scale and mass-production requirements.

  • Technical Support and Service System​

    ERDI maintains technical service centers and distribution partners worldwide, enabling rapid customer response.
    We provide:

    • Comprehensive technical consultation and project evaluation
    • One-on-one on-site technical assistanceat the customer’s facility when required
    • Lifetime after-sales supportand technical maintenance guidance

    Each laser product is delivered with a full set of user documentation, including Laser Module Usage Precautions and Safety Guidelines.

  • Quality Assurance and Warranty​

    ERDI implements strict multi-stage quality control throughout production:

    • Incoming material inspection
    • Optical alignment verification
    • Output power and wavelength calibration
    • Safety and durability testing under standard conditions

    We guarantee that all products leaving our factory meet design and performance specifications.
    Except for man-made damage, we will replace any defective unit within one year free of charge and provide lifetime maintenance support thereafter.

    For more details, please refer to our After-Sales Service & Warranty Policy.

  • Important Safety Reminder

    Before using any ERDI laser product:

    • Carefully read and follow the Laser Module Usage Precautions.
    • Always use appropriate laser protective eyewear.
    • Operate only in controlled environmentsunder trained personnel supervision.
      Failure to observe safety instructions may result in injury or equipment damage.
  • Communication and Order Confirmation​

    To ensure efficient service, please confirm the following before placing an order:

    • Product model, wavelength, output power, and working voltage/current
    • Whether you require custom mechanical dimensions, optical configurations, or driver circuitry.
    • Packaging, labeling, and shipping preferences.
    • Any specific export or compliance documentation needed for your country.

    Our sales engineers will provide an official quotation and delivery schedule upon confirmation of all specifications.

  • Final Statement​

    ERDI upholds the values of safety, integrity, and precision. We sincerely welcome customers from all over the world to visit our facilities, discuss cooperation, and experience our advanced laser technologies firsthand. Your satisfaction and trust are our highest pursuit.

After-Sales Service & Warranty Policy

We strive to provide high-quality laser modules and excellent customer service. Please read the following terms carefully to understand your rights and our responsibilities.

  • Product Origin and Quality Assurance​

    • All ERDI products are manufactured directly by the factory, ensuring consistent quality and full traceability.
    • We provide a diverse rangeof laser modules and laser distance measurement modules to suit various industrial, educational, and research applications.
    • Every product is tested and inspectedbefore shipment to guarantee that it meets specification standards.
  • Return and Exchange Policy​

    • Customers may request a return or exchange within 30 daysof receiving the goods, provided that:
    • The product remains in original condition, unused, and without affecting secondary sales.
    • A valid reason for return or exchangeis provided.
    • Upon approval, we will replace or refund according to our service policy.
    • The buyer is responsible for shipping costsassociated with returns, exchanges, or repairs, based on international freight cost rules.
  • Warranty Coverage​

    • The main functional componentsof ERDI laser products are covered by a 2-year warranty from the date of purchase, excluding cosmetic appearance.
    • Within the first 12 months, if a verified manufacturing defect occurs, we will replace the item with a brand-new productfree of charge.
    • Replacement of cosmetic or housing components (e.g., enclosure, labeling, or exterior parts) may incur a reasonable cost feebased on material expenses.
    • Warranty does not cover:
    • Damage due to misuse, improper installation, or modification.
    • Operation outside the recommended power supply or temperature range.
    • Accidental or physical damage, including drops, fire, or liquid ingress.
  • Receiving Inspection​

    • Upon delivery, please inspect the parcel immediately in the presence of the courier.
    • If there is any quantity discrepancy, visible damage, or mismatch, do not signthe delivery receipt.
    • Once the package is signed for (by you, family, or colleagues), it is considered accepted as correct and complete.
  • Customer Support

    For technical assistance, warranty claims, or safety inquiries, please contact our official service team through the contact information listed on erdicn.com.
    Our support engineers will provide professional guidance on installation, alignment, safety, and maintenance procedures.

Laser Module Usage Precautions

(Important – Buyers Must Read Before Use)

Operating laser modules involves potential optical and thermal hazards. To ensure safe and proper use, please read the following precautions carefully before powering on your laser product.

  • General Safety Warnings​

    • Invisible Radiation Warning– Some laser modules emit infrared (IR) or ultraviolet (UV) radiation that is invisible to the human eye. Never assume the laser is malfunctioning simply because you cannot see the beam. Always confirm that the power is disconnected before inspecting the module.
    • Do Not Look Directly into the Laser Aperture– Even when wearing certified laser safety goggles, never stare directly into or near the beam exit of a working laser module.
    • Avoid Reflected Beams from High-Power Lasers– Reflection from Class IV lasers (output power > 500 mW) can cause severe and permanent eye damage. Always wear wavelength-specific safety goggles when operating or aligning high-power laser systems.
    • Keep Away from Flammable Materials– Do not place flammable or explosive items (such as paper, cloth, leather, or plastics) in the laser path. Black or dark-colored materials absorb laser energy more easily and may ignite. (Exception: controlled material-burning experiments with proper fire protection.)
    • Avoid Direct Human Exposure– Class IIIa or higher lasers (≥ 5 mW) can burn skin or eyes. Never point a laser beam at any part of a person’s body.
    • Restrict Access to Trained Personnel Only – Keep all laser devices out of reach of untrained individuals, children, and pets.
  • Optical Path and Reflection Safety​

    • Never Aim Toward Glass Surfaces– Ordinary glass reflects roughly 4 % of incident light, which can redirect dangerous laser radiation into your eyes. Avoid operating lasers in front of mirrors or reflective windows.
    • Working Plane Awareness– When setting up an experimental platform, note the laser emission height. Do not position your head or eyes near this level during operation. Lenses and mirrors may reflect or refract light unexpectedly. Always align optical components downward or horizontally—never angle a beam upward.
    • Remove Reflective Accessories– Watches, jewelry, and other shiny objects can reflect laser light unpredictably. Remove them before use.
    • Infrared Beam Detection– IR lasers (wavelength > 800 nm) are almost completely invisible. Use a beam-viewing card, IR detector, or up-conversion screen to visualize the beam path safely.
    • Visual Brightness Misjudgment– Some wavelengths (below 430 nm or above 700 nm) appear much dimmer than their actual power output. Do not rely on visual brightness to judge beam intensity.
    • Pulsed Laser Caution– Pulsed lasers can have extremely high peak power even at modest average power levels. Verify that all optical elements and samples in your experiment exceed the laser’s damage threshold before exposure.
    • Prohibited Uses– It is strictly forbidden to point laser beams at moving vehicles, aircraft, or any area where light could distract or endanger others.
    • End-of-Beam Safety Stop– Always place a black anodized or matte metal plate at the end of your optical path to absorb residual energy and prevent laser leakage into surrounding areas.

    Low-Power Modules – ERDI laser modules rated below 1 mW are considered eye-safe under normal operating conditions and can be used without hazard when handled properly.

  • Recommended Protective Measures​

    • Protective Eyewear– Always wear certified laser safety goggles designed for the specific wavelength and power level of your module.
    • Appropriate Clothing– Light-colored or white long-sleeved clothing reduces the risk of heat absorption or ignition if stray laser light contacts the fabric.
    • UV Laser Protection– For ultraviolet lasers, apply broad-spectrum sunscreen (SPF 30 or higher) to exposed skin areas to minimize UV radiation effects.
    • Environmental Safety– Operate lasers in a controlled laboratory or industrial environment with minimal reflective surfaces. Ensure that all personnel nearby are informed of ongoing laser use and have received proper training.

TECHNICAL SPECIFICATIONS

Model

ER300

Laser Wavelength

1535nm

Eye safe

Class 1

Pulse energy

≥300 μJ

Laser Pulse width

5 ns

Drive pulse width

≤2.4 ms

Pulse repetition rate

1~10Hz

Pulse stability

10%

Raw Beam Diameter

0 .3 mm

Beam divergence angle

≤ 7 mrad

Beam Mode

TEM00

Operating temperature

-40 ℃ ~ +65 ℃

Storage temperature

-55 ℃ ~+ 75℃

Dimension (mm)

25×8×6.8 mm3

Weight

8.5 g

Voltage

2 V

Electric current

12 A

Shock

1500 G, 0.5 ms

Vibration

20~2000 Hz/20 G

Lifetime

>1million shots

OUTLINE DIMENSION

ER300 1535nm 300µJ Eye-Safe Erbium Glass Microchip DPSS Laser

Figure 1 Outline Dimensions (mm)

Operating Instructions

  • Match the laser driver to the ER200 laser.
    The laser driver power supply must be properly matched to the laser.
    The typical load voltage of the ER200 is < 2 V, with an operating current of 10 A, pulse width < 2 ms, and a repetition rate of 10 Hz. For the exact operating parameters, please refer to the attached factory test report.
    The laser driver power supply must meet these requirements; otherwise, the laser may fail to operate properly or could be overloaded and permanently damaged. Therefore, before wiring, carefully check the laser specification sheet and confirm that the laser is compatible with the selected driver.

  • Always disconnect power before wiring.
    Before making any connections, make sure the power is switched off and completely isolated.
    When wiring, carefully check the positive and negative terminals of the laser and ensure correct polarity. After the wiring is completed, perform a thorough inspection to confirm that all connections are correct, in order to avoid short circuits, reverse polarity, and other faults. At the same time, make sure all terminals are firmly secured to prevent poor contact due to loose wiring.

  • Set operating parameters according to the factory test report.
    After confirming that the wiring is correct, set the corresponding parameters on the driver according to the attached factory test report.
    Once the parameters are correctly set, turn on the driver; the laser should then operate normally.

  • Keep the laser output window clean.
    Take care to keep the laser output window clean and do not touch the window surface.
    If contamination occurs, clean the window thoroughly before operating the laser.

Product Description

ER300 1535nm 300µJ Eye-Safe Erbium Glass Microchip DPSS Laser

The ER300 is a 1.54µm, 1535nm eye-safe erbium glass microchip DPSS laser developed as a compact pulse source for long-range LiDAR, laser rangefinding and target designation tasks. It combines a diode-pumped Er³⁺:glass gain medium with a microchip resonator to deliver nanosecond pulses in a very small, board-level package that can be embedded in OEM systems where space and weight are tightly constrained.

The ER300 provides ≥300µJ single-pulse energy with a typical pulse width of 5ns and a repetition rate adjustable from 1 to 10Hz. Raw beam diameter is about 0.3mm and the divergence is ≤7mrad in a TEM₀₀ mode, which makes it straightforward to collimate or feed into a small-aperture transmit optic while maintaining good beam quality. Pulse stability is specified at 10%, supporting consistent performance for time-of-flight ranging and LiDAR point-cloud generation.

Designed for demanding outdoor environments, the laser operates from −40°C to +65°C and can be stored from −55°C to +75°C. It passes shock testing at 1500G / 0.5ms and vibration testing from 20–2000Hz at 20G, and the specified lifetime exceeds 1 million shots, giving system designers confidence in long-term field deployment. The module measures only 25×8×6.8mm³ and weighs about 8.5g, so it can be mounted directly on driver boards inside compact rangefinder or LiDAR modules.

Electrically, the ER300 is driven from a low-voltage, high-current pulse: typical load voltage is <2V, operating current is 12A, drive pulse width ≤2.4ms and repetition rate up to 10Hz. To protect the device, the driver must be correctly matched to these parameters; the specification sheet and factory test report are used as the reference for setting voltage, current, pulse width and PRF before enabling emission. Proper wiring practice is emphasized: power must be disconnected before connection, polarity must be carefully checked and all contacts should be secure to avoid short circuits, reverse polarity and intermittent connections.

Operating instructions also highlight the need to keep the laser output window clean. The window surface should not be touched; if contamination appears, it should be cleaned before use to prevent energy loss and potential damage. When integrated into a complete laser-ranging or LiDAR system, the ER300 acts as the transmitter core: its nanosecond pulse is expanded and collimated by the transmit optics, reflected from the target and detected at the receiver by an InGaAs APD matched to 1.5µm, with a TDC providing precise time-of-flight measurement.

Thanks to the 1.5µm wavelength, the ER300 works in an eye-safer regime and benefits from low atmospheric attenuation and strong penetration in haze, rain and aerosol conditions. Typical application scenarios include handheld and weapon-mounted laser rangefinders, micro and small UAV LiDAR payloads, EO/IR pods requiring an embedded 1535nm source, topographic mapping systems, industrial structural monitoring and robot navigation, as well as microjoule-to-millijoule-level hybrid architectures where ERDI’s erbium glass lasers are the core pulse engine.

 

300µJ 1.54µm erbium glass microchip DPSS laser for multi-kilometer rangefinders 300µJ 1.54µm erbium glass microchip DPSS laser for multi-kilometer rangefinders 300µJ 1.54µm erbium glass microchip DPSS laser for multi-kilometer rangefinders 300µJ 1.54µm erbium glass microchip DPSS laser for multi-kilometer rangefinders 300µJ 1.54µm erbium glass microchip DPSS laser for multi-kilometer rangefinders 300µJ 1.54µm erbium glass microchip DPSS laser for multi-kilometer rangefinders