The ER4000 is a 4mJ 1535nm eye-safe erbium glass microchip DPSS laser that delivers 12ns TEM00 pulses at 1–10Hz with ≤4mrad divergence in a 60×25×13.5mm, 105g head. Qualified to MIL-style shock and vibration with a lifetime >1 million shots, it is a compact Class 1 source for long-range LiDAR, rangefinding, infrared sensing, medical and communication systems.

数量

Contact Us

Senior Engineer, Yilin

Tel : +86 28 81076698

WhatsApp : +86 18000520222

ERDI Pre-Sales Notice & Customer Information

(Please Read Before Purchase or Inquiry) Thank you for your interest in ERDI TECH LTD. We are committed to providing customers worldwide with high-precision, high-reliability laser products and technical solutions. Before placing an order, please read the following information carefully to better understand our company, services, and purchasing policies.

  • About ERDI​

     ERDI is a professional manufacturer specializing in the research, development, and production of laser modules, laser measurement systems, and related optoelectronic components.
    We integrate design, R&D, production, and sales, with a focus on safety, innovation, and precision.

    Our products are widely used in:

    • Industrial measurement and alignment systems
    • Scientific research and educational applications
    • Optical instrumentation and laser testing
    • Consumer and OEM laser solutions

    ERDI operates certified facilities and maintains rigorous quality control to ensure that every product meets international standards.

  • Global Presence and Trade Reliability​

    ERDI has established official stores on leading global platforms including Amazon, Alibaba International Station, and Made-in-China.com, allowing customers worldwide to purchase safely and conveniently. We are a verified and trusted factory, not a reseller, and we ensure that all transactions, quotations, and logistics follow transparent and secure trade practices.
  • Sample and Lead Time​

    To help customers evaluate our products and performance, we offer sample orders for most product categories.

    • Standard samplesare typically delivered within one week after order confirmation.
    • Customized modulesmay require additional processing time depending on design complexity and optical requirements.
      Our logistics team will provide real-time tracking and documentation for every shipment.
  • OEM / ODM / OBM Services​

     ERDI supports full-range customization including:

    • OEM (Original Equipment Manufacturing)– Products manufactured under your brand or part number.
    • ODM (Original Design Manufacturing)– Custom optical or mechanical design based on your specifications.
    • OBM (Original Brand Manufacturing)– Private-label solutions with our in-house R&D and branding support.

    We provide technical co-development, logo engraving, packaging customization, and batch production services to meet both small-scale and mass-production requirements.

  • Technical Support and Service System​

    ERDI maintains technical service centers and distribution partners worldwide, enabling rapid customer response.
    We provide:

    • Comprehensive technical consultation and project evaluation
    • One-on-one on-site technical assistanceat the customer’s facility when required
    • Lifetime after-sales supportand technical maintenance guidance

    Each laser product is delivered with a full set of user documentation, including Laser Module Usage Precautions and Safety Guidelines.

  • Quality Assurance and Warranty​

    ERDI implements strict multi-stage quality control throughout production:

    • Incoming material inspection
    • Optical alignment verification
    • Output power and wavelength calibration
    • Safety and durability testing under standard conditions

    We guarantee that all products leaving our factory meet design and performance specifications.
    Except for man-made damage, we will replace any defective unit within one year free of charge and provide lifetime maintenance support thereafter.

    For more details, please refer to our After-Sales Service & Warranty Policy.

  • Important Safety Reminder

    Before using any ERDI laser product:

    • Carefully read and follow the Laser Module Usage Precautions.
    • Always use appropriate laser protective eyewear.
    • Operate only in controlled environmentsunder trained personnel supervision.
      Failure to observe safety instructions may result in injury or equipment damage.
  • Communication and Order Confirmation​

    To ensure efficient service, please confirm the following before placing an order:

    • Product model, wavelength, output power, and working voltage/current
    • Whether you require custom mechanical dimensions, optical configurations, or driver circuitry.
    • Packaging, labeling, and shipping preferences.
    • Any specific export or compliance documentation needed for your country.

    Our sales engineers will provide an official quotation and delivery schedule upon confirmation of all specifications.

  • Final Statement​

    ERDI upholds the values of safety, integrity, and precision. We sincerely welcome customers from all over the world to visit our facilities, discuss cooperation, and experience our advanced laser technologies firsthand. Your satisfaction and trust are our highest pursuit.

After-Sales Service & Warranty Policy

We strive to provide high-quality laser modules and excellent customer service. Please read the following terms carefully to understand your rights and our responsibilities.

  • Product Origin and Quality Assurance​

    • All ERDI products are manufactured directly by the factory, ensuring consistent quality and full traceability.
    • We provide a diverse rangeof laser modules and laser distance measurement modules to suit various industrial, educational, and research applications.
    • Every product is tested and inspectedbefore shipment to guarantee that it meets specification standards.
  • Return and Exchange Policy​

    • Customers may request a return or exchange within 30 daysof receiving the goods, provided that:
    • The product remains in original condition, unused, and without affecting secondary sales.
    • A valid reason for return or exchangeis provided.
    • Upon approval, we will replace or refund according to our service policy.
    • The buyer is responsible for shipping costsassociated with returns, exchanges, or repairs, based on international freight cost rules.
  • Warranty Coverage​

    • The main functional componentsof ERDI laser products are covered by a 2-year warranty from the date of purchase, excluding cosmetic appearance.
    • Within the first 12 months, if a verified manufacturing defect occurs, we will replace the item with a brand-new productfree of charge.
    • Replacement of cosmetic or housing components (e.g., enclosure, labeling, or exterior parts) may incur a reasonable cost feebased on material expenses.
    • Warranty does not cover:
    • Damage due to misuse, improper installation, or modification.
    • Operation outside the recommended power supply or temperature range.
    • Accidental or physical damage, including drops, fire, or liquid ingress.
  • Receiving Inspection​

    • Upon delivery, please inspect the parcel immediately in the presence of the courier.
    • If there is any quantity discrepancy, visible damage, or mismatch, do not signthe delivery receipt.
    • Once the package is signed for (by you, family, or colleagues), it is considered accepted as correct and complete.
  • Customer Support

    For technical assistance, warranty claims, or safety inquiries, please contact our official service team through the contact information listed on erdicn.com.
    Our support engineers will provide professional guidance on installation, alignment, safety, and maintenance procedures.

Laser Module Usage Precautions

(Important – Buyers Must Read Before Use)

Operating laser modules involves potential optical and thermal hazards. To ensure safe and proper use, please read the following precautions carefully before powering on your laser product.

  • General Safety Warnings​

    • Invisible Radiation Warning– Some laser modules emit infrared (IR) or ultraviolet (UV) radiation that is invisible to the human eye. Never assume the laser is malfunctioning simply because you cannot see the beam. Always confirm that the power is disconnected before inspecting the module.
    • Do Not Look Directly into the Laser Aperture– Even when wearing certified laser safety goggles, never stare directly into or near the beam exit of a working laser module.
    • Avoid Reflected Beams from High-Power Lasers– Reflection from Class IV lasers (output power > 500 mW) can cause severe and permanent eye damage. Always wear wavelength-specific safety goggles when operating or aligning high-power laser systems.
    • Keep Away from Flammable Materials– Do not place flammable or explosive items (such as paper, cloth, leather, or plastics) in the laser path. Black or dark-colored materials absorb laser energy more easily and may ignite. (Exception: controlled material-burning experiments with proper fire protection.)
    • Avoid Direct Human Exposure– Class IIIa or higher lasers (≥ 5 mW) can burn skin or eyes. Never point a laser beam at any part of a person’s body.
    • Restrict Access to Trained Personnel Only – Keep all laser devices out of reach of untrained individuals, children, and pets.
  • Optical Path and Reflection Safety​

    • Never Aim Toward Glass Surfaces– Ordinary glass reflects roughly 4 % of incident light, which can redirect dangerous laser radiation into your eyes. Avoid operating lasers in front of mirrors or reflective windows.
    • Working Plane Awareness– When setting up an experimental platform, note the laser emission height. Do not position your head or eyes near this level during operation. Lenses and mirrors may reflect or refract light unexpectedly. Always align optical components downward or horizontally—never angle a beam upward.
    • Remove Reflective Accessories– Watches, jewelry, and other shiny objects can reflect laser light unpredictably. Remove them before use.
    • Infrared Beam Detection– IR lasers (wavelength > 800 nm) are almost completely invisible. Use a beam-viewing card, IR detector, or up-conversion screen to visualize the beam path safely.
    • Visual Brightness Misjudgment– Some wavelengths (below 430 nm or above 700 nm) appear much dimmer than their actual power output. Do not rely on visual brightness to judge beam intensity.
    • Pulsed Laser Caution– Pulsed lasers can have extremely high peak power even at modest average power levels. Verify that all optical elements and samples in your experiment exceed the laser’s damage threshold before exposure.
    • Prohibited Uses– It is strictly forbidden to point laser beams at moving vehicles, aircraft, or any area where light could distract or endanger others.
    • End-of-Beam Safety Stop– Always place a black anodized or matte metal plate at the end of your optical path to absorb residual energy and prevent laser leakage into surrounding areas.

    Low-Power Modules – ERDI laser modules rated below 1 mW are considered eye-safe under normal operating conditions and can be used without hazard when handled properly.

  • Recommended Protective Measures​

    • Protective Eyewear– Always wear certified laser safety goggles designed for the specific wavelength and power level of your module.
    • Appropriate Clothing– Light-colored or white long-sleeved clothing reduces the risk of heat absorption or ignition if stray laser light contacts the fabric.
    • UV Laser Protection– For ultraviolet lasers, apply broad-spectrum sunscreen (SPF 30 or higher) to exposed skin areas to minimize UV radiation effects.
    • Environmental Safety– Operate lasers in a controlled laboratory or industrial environment with minimal reflective surfaces. Ensure that all personnel nearby are informed of ongoing laser use and have received proper training.

TECHNICAL SPECIFICATIONS

Model

ER4000

Laser Wavelength

1535nm

Eye safe

Class 1

Pulse energy

≥4 mJ

Laser Pulse width

12 ns

Drive pulse width

≤ 4 ms

Pulse repetition rate

1~5Hz

Pulse stability

10%

Raw Beam Diameter

0 .5 mm

Beam divergence angle

≤ 4mrad

Beam Mode

TEM00

Operating temperature

-40 ℃ ~ +65 ℃

Storage temperature

-55 ℃ ~+ 75℃

Dimension (mm)

60×25×13.5mm3

Weight

105 g

Voltage

≤ 5 V

Electric current

100 A

Shock

1500 G, 0.5 ms

Vibration

20~2000 Hz/20 G

Lifetime

>1million shots

OUTLINE DIMENSION

ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems

Figure 1 Outline Dimensions (mm)

Operating Instructions

  1. Match the laser driver to the ER4000 laser.
    The laser driver power supply must be properly matched to the laser.
    The typical load voltage of the ER4000 is < 5 V, with an operating current of 100 A, pulse width < 4 ms, and a repetition rate of 5 Hz. For the exact operating parameters, please refer to the attached factory test report.
    The laser driver power supply must meet these requirements; otherwise, the laser may fail to operate properly or could be overloaded and permanently damaged. Therefore, before wiring, carefully check the laser specification sheet and confirm that the laser is compatible with the selected driver.

  2. Always disconnect power before wiring.
    Before making any connections, make sure the power is switched off and completely isolated. During wiring, carefully check the positive and negative terminals of the laser and ensure correct polarity. After the wiring is completed, perform a thorough inspection to confirm that all connections are correct, in order to avoid short circuits, reverse polarity, and other faults. At the same time, make sure all terminals are firmly secured to prevent poor contact due to loose wiring.

  3. Set operating parameters according to the factory test report.
    After confirming that the wiring is correct, set the corresponding parameters on the driver according to the attached factory test report. Once the parameters are correctly set, turn on the driver; the laser should then operate normally.

Product Description

ER4000 1.54µm / 1535nm 4mJ Eye-Safe Erbium Glass Microchip DPSS Laser

The ER4000 is a 4mJ 1535nm eye-safe erbium glass microchip DPSS laser developed as a high-energy core for long-range LiDAR, precision laser rangefinders, infrared sensing and selected medical and communication systems. It uses an LD-pumped Er:glass gain medium in a compact resonator to generate nanosecond pulses at a Class 1 eye-safe wavelength, combining millijoule-level energy with a small, integration-friendly package.

The laser delivers ≥4mJ pulse energy with a typical pulse width of 12ns and a repetition rate adjustable from 1 to 10Hz. Pulse stability is about 10%. The raw beam diameter is ~0.5mm, the full-angle divergence is ≤4mrad and the mode is TEM₀₀, so users get a clean, well-collimated beam that is easy to expand for long-range LiDAR or to couple into compact transmit optics, scanners or fiber couplers.

Mechanically, the ER4000 fits into a 60×25×13.5mm³ housing and weighs about 105g, giving designers a 4mJ, 1535nm source that still fits inside pods, turrets and instrument bays where space is at a premium. Electrically, the typical load voltage is <5V with a high drive current of roughly 100A, drive pulse width ≤4ms and nominal repetition rate around 5Hz, adjustable in the 1–10Hz range. The driver must be properly matched to these parameters; otherwise the laser may fail to start correctly or may be overloaded and permanently damaged.

The ER4000 is built for harsh outdoor environments. It operates from −40°C to +65°C and can be stored between −55°C and +75°C. It withstands 1500G shock with 0.5ms duration and 20–2000Hz vibration at 20G, and the specified lifetime exceeds 1 million shots, which aligns with long-life LiDAR, rangefinding and sensor payload requirements.

Beyond classic laser rangefinders and LiDAR, 1535nm Er:glass sources are widely used in target recognition, laser radar, laser medical treatment and optical-fiber communication links, thanks to eye-safety and compatibility with telecom-grade components. The strong water absorption near 1.5µm also allows controlled energy deposition in water-rich tissues, enabling non-ablative skin treatments and other medical procedures, while the low atmospheric attenuation and good penetration in fog, rain and aerosol make the ER4000 suitable for meteorological LiDAR, obstacle-avoidance radar and environmental sensing. 

Operation instructions focus on driver matching and safe wiring. Before any connection, the power supply must be completely switched off and isolated. During wiring, the positive and negative terminals must be checked carefully and all contacts must be firmly secured to avoid short circuits, reverse polarity or intermittent connections. After wiring, the driver parameters—voltage, current, pulse width and repetition rate—should be set according to the attached factory test report; once these are confirmed, the driver can be enabled and the ER4000 should operate normally.

Taken together, the 4mJ pulse energy, eye-safe wavelength, TEM₀₀ beam quality, compact size and MIL-grade environmental performance make the ER4000 a versatile 1535nm platform laser for long-range LiDAR channels, high-end rangefinders, advanced sensing nodes, medical devices and fiber or free-space optical links where both safety and performance matter.

ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems ER4000 4mJ 1535nm Eye-Safe Erbium Glass Laser for LiDAR, Sensing and Medical Systems

Ralated Products